Signal Repeater - MOFR
|
The MOFR is a compact DIN rail mountable signal repeater that performs a number of tasks, including converting time sync signals from fiber optics to copper (and vice versa), boosting signal strengths and converting one type of signal to another. As the MOFR is completely electronically isolated, it will also provide your IEDs (Intelligent Electronic Devices) with an additional layer of electrical protection.
|
![]() open 3D view |
| Isolated power supply |
| High line drivers |
| Low noise characteristics due to balanced pair distribution |
| Ability to extend the distance of an IRIG-B or pulse signal |
| Provides isolation between protection systems |
| Copper to fibre/ fibre to copper |
| DC Level Shift (DCLS) to TTL, RS232, RS422/485 and AM IRIG-B |
| DCLS to HV MOSFET |
| Click here for a PDF version of the specifications. (155KB) |
| Physical | |
| UL94-V0 polycarbonate flame retardant din rail mount case with IP20 (Ingress Protection rating). | |
| Dimensions: | (W) 55mm x (D) 60mm x (H) 90mm |
| Weight: | 0.15Kg |
| LED Indicators: | Green: Power Red: Input signal indicator |
| Environmental & Electrical | |
| Power supply: | L = 12-36Vdc M = 20-72Vdc H = 90-300Vdc |
| Power drain: | 3W max |
| Operating Temperature: | -10°C to +65°C |
| Humidity: | To 95% non-condensing |
| Isolation: | Power to I/O: 1kV Input to outputs: 3.5kV (min) |
| Inputs & Outputs | |
| Copper input specs: | Input burden: 12V 7mA max Supports TTL, RS232, RS422/ RS485 |
| Fiber input specs: | ST Fiber connector: Λ = 820nm Compatability: 62.5/125um multi-mode fiber |
| Low voltage output specs: | Drive line rating: TTL = 0—5V 75mA RS422 = ±5V 50 RS422 loads RS232 = ±10V 15mA |
| High voltage output specs: | Switching capability: 300V, 1A Technology: High speed MOSFET |
| Options | |
| Option D: | Converts a fiber or copper digital IRIG-B signal to AM IRIG-B. This function replaces the secondary AM IRIG-B Input. |
| Option H: | High Voltage Output HV MOSFET replaces the Primary Low Voltage Outputs. |
| MOFR Copper version | |
| Inputs: |
Primary Inputs: Secondary Input: 1 x Copper AM IRIG-B |
| Outputs: | Low voltage Outputs: 1 x Copper TTL 1 x Copper RS232 1 x Copper RS422/RS485
Secondary Output: 1 x Copper AM IRIG-B |
| MOFR Fiber version | |
| Inputs: |
Primary Inputs: Secondary Input: 1 x Copper AM IRIG-B |
| Outputs: | Primary Outputs: 1 x ST Fiber 1 x Copper TTL 1 x Copper RS232 1 x Copper RS422/RS485
Secondary Output: 1 x Copper AM IRIG-B |
| Copper version additional features | |
| In addition to the primary and secondary inputs, copper version MOFRs also provide “Term” and “Loop” connectors. | |
| Term terminal: | All copper version MOFRs contain a 150 terminating resistor for terminating the end of a line of multi-dropped or daisy chained MOFRs to prevent signal reflection. To terminate the end of a line, simply connect a wire between the two Term connectors. |
| Loop terminal: | All copper version MOFRs provide a loop terminal which is common to the primary input. This provides a simplified way of multi-dropping MOFRs without having to install two wires into the same input, or install splitters. |
| MOFR datasheet (155KB) | |
| The PDF guides below give a brief overview of the functional differences between each version of the MOFR. | |
| MOFR01-2HA The primary input in the MOFR01-2HA accepts DCLS IRIG-B or digital pulses. When a DCLS IRIG-B signal or digital pulse is received on the primary input, the MOFR isolates and regenerates the signal on the primary output at a voltage dictated by an external DC power source. This model also has a secondary input which accepts AM IRIG-B. The sole purpose of the secondary input is to provide isolation and it does not regenerate or amplify the signal. [Click here for the guide. (400 KB)] |
|
| MOFR01-2HD The primary input in the MOFR01-2HD accepts DCLS IRIG-B or digital pulses. When a DCLS IRIG-B signal or digital pulse is received on the primary input, the MOFR isolates, and regenerates the signal on the primary output at a voltage dictated by an external DC power source. If a DCLS IRIG-B signal is received on the input, the MOFR will isolate, and regenerate the signal as AM IRIG-B. [Click here for the guide. (400 KB)] |
|
| MOFR01-2LA The primary input in the MOFR01-2LA accepts DCLS IRIG-B or digital pulses. When a DCLS IRIG-B signal or digital pulse is received on the primary input, the MOFR isolates, regenerates and amplifies the signal in TTL, RS232 and RS422/ 485 simultaneously on the primary outputs. This model also has a secondary input which accepts AM IRIG-B. The sole purpose of the secondary input is to provide isolation and it does not regenerate or amplify the signal. [Click here for the guide. (400 KB)] |
|
| MOFR01-2LD The input in the MOFR01-2LD accepts DCLS IRIG-B or digital pulses. When a DCLS IRIG-B signal or digital pulse is received on the input, the MOFR isolates, regenerates and amplifies the signal in TTL, RS232 and RS422/ 485 simultaneously on the outputs. If a DCLS IRIG-B signal is received on the input, the MOFR will isolate, and regenerate the signal as AM IRIG-B. [Click here for the guide. (400 KB)] |
|
| MOFR01-5HA The primary copper and fiber inputs in the MOFR01-5HA accept DCLS IRIG-B or digital pulses. When a DCLS IRIG-B signal or digital pulse is received on one of the primary inputs, the MOFR isolates, and regenerates the signal on the primary fiber output, as well as the copper output at a voltage dictated by an external DC power source. This model also has a secondary input which accepts AM IRIG-B. The sole purpose of the secondary input is to provide isolation and it does not regenerate or amplify the signal. [Click here for the guide. (400 KB)] |
|
| MOFR01-5LA The primary copper and fiber inputs in the MOFR01-5LA accept DCLS IRIG-B or digital pulses. When a DCLS IRIG-B signal or digital pulse is received on one of the primary inputs, the MOFR isolates, regenerates and amplifies the signal on the primary fiber, TTL, RS232 and RS422/ 485 outputs simultaneously. This model also has a secondary input which accepts AM IRIG-B. The sole purpose of the secondary input is to provide isolation and it does not regenerate or amplify the signal. [Click here for the guide. (400 KB)] |
|
| MOFR01-5LD The primary copper and fiber inputs in the MOFR01-5LD accept DCLS IRIG-B or digital pulses. When a DCLS IRIG-B signal or digital pulse is received on one of the primary inputs, the MOFR isolates, regenerates and amplifies the signal on the primary fiber, TTL, RS232 and RS422/ 485 outputs simultaneously. If a DCLS IRIG-B signal is received on the copper or fiber input, the MOFR will isolate, and regenerate the signal as AM IRIG-B. [Click here for the guide. (400 KB)] |
|